Laboratory Gas Detection and Monitoring System

GAS DETECTION SOLUTIONS FOR LABORATORY

In Laboratory environments many gas types are used in testing, experiments or process application simulations. These can be inert, toxic and flammable, so gas monitoring is essential to maintain a safe environment for employees. The gas types can cause asphyxiation, so early detection of rising gas levels can be detected by our gas sensors and immediately activate audio/visual alarms and switch on necessary extraction fans. Common Laboratory and Classroom gas types include but not limited to Carbon dioxide, Nitrogen, Natural Gas and also enriched Oxygen, all these mentioned gas types are harmful when the recommended exposure limits are surpassed. Any gas leakage in Laboratory environments need to be identified promptly to ensure the Health and Safety of staff or students within these areas.

REFRIGERANT ROOM TYPES MONITORED

  • R&D Laboratories
  • Production Laboratories
  • Medical Laboratories
  • Quality and Analytics Laboratories

DIRECT CONNECTION TO A CENTRAL MONITORING SYSTEM

Our fixed gas detectors can be connected directly to a central monitoring system to make sure that the areas of interest can be continuously monitored for the gas type level statuses. We also connected our Laboratory Gas Monitoring systems to audio visual pre alarm indicators, including sounder/beacons for local annunciation of a potential issue so that swift action can be taken.

RECOMMENDED GAS DETECTION ELEMENTS:

CODE

NAME

DESCRIPTION

10100002

DEGA UPA III 8

Gas Detection Control Panel (max. 8 transmitters/detectors in 1 line (BUS). Input: 1 x RS485 x 8 pcs. Outputs: 3 x Relays and 2 x Output for Optical and Acoustic Signalisation, 1 x Output for External Button, 1 x USB. Power Supply: 24 VDC, HS: 85318070

10200019

DEGA UPA III Power

Internal Power Supply 230 VAC/15 VA

10200020

DEGA UPA III Relay Module

Internal Output, 7-relays, 250 V/10 A

10200021

DEGA UPA III RS485 Modbus RTU Module

Internal Output RS485 Modbus RTU

10200022

DEGA UPA III 4-20 mA Input Module

Internal Input 4-20 mA

10200023

DEGA UPA III Memory Module

Internal memory with battery

10300012

Cable Glands PG9 (10 pcs)

Cable Glands PG9 (10 pcs)

20100028

DEGA NBCO-EL 1000 III

Transmitter, Carbon monoxide with filter, 0-1000 ppm, Electrochemical, 4-20mA, RS485 (DEGA), 24 VDC, HS:9027101000

20100058

DEGA NBO2-EL 30 III

Transmitter, Oxygen, 0-30% vol., Electrochemical, 4-20mA, RS485 (DEGA), 24 VDC, HS:9027101000

20100061

DEGA NBO3-EL 5 III

Transmitter, Ozone, 0-5 ppm high sensitivity, Electrochemical, 4-20mA, RS485 (DEGA), 24 VDC, HS:9027101000

20100095

DEGA NBVOC-PID III

Transmitter, VOCs 10.6 eV Complete, 0-3000 ppm, PID, 4-20mA, RS485 (DEGA), 24 VDC, HS:9027101000

20100052

DEGA NBNO-EL 250 III

Transmitter, Nitric oxide, 0-250 ppm, Electrochemical, 4-20mA, RS485 (DEGA), 24 VDC, HS:9027101000

50100004

DEGA PANEL S1 III (24 VDC)

Single-sided red LED panel (500x200x28 mm), IP 65, -25°C +70°C, (safe area). Text: “!DO NOT ENTER! Dangerous concentration of gas”.

50100004

DEGA PANEL S1 III (24 VDC)

Single-sided red LED panel (500x200x28 mm), IP 65, -25°C +70°C, (safe area). Text: “!LEAVE THE AREA! Dangerous concentration of gas”.

50200003

DEGA S II

External acoustic signaling (safe area)

Modules

SIGNALISATION
TRANSMITTERS AND DETECTORS
GAS DETECTION CONTROL PANELS

Professional request

Insert file

Feedback


Tento web je chráněn reCAPTCHA a platí zásady ochrany osobních
údajů a podmínky služby Google